• Description

Product Description

China 0.5%Accuracy Insertion Type Thermal Air Gas Mass

Insertion Type Mass Flowmeter, Air Flowmeter, 2 Vortex Flowmeter manufacturer / supplier in China, offering 0.5%Accuracy Insertion Type Thermal Air Gas Mass Flowmeter, Hxe012 RS485 IP68 Protection Level Electromagnetic Water Meter, Hgf900 High Temperature High Pressure Magnetic Flap Liquid Level Gauge/Level Meter/Level Transmitter and so on.

China Air Vortex Flow Meter Ammonia Gas Flow Meter

In gas measurement, vortex flow meter could achieve high accuracy ±0.75%~±1.0% of reading ( gas ±1.0%, liquid ±0.75%); which could use in custody transfer , while the metal tube rotameter or orifice plate usually use for process control. China Inline Thermal Gas Mass Flow Meter Manufacturers Maintenance of Inline Thermal Gas Mass Flow Meter. 1. When opening the enclosure, power off first. 2. When removing the sensor, pay attention to the non-toxic nature of the pipeline pressure, temperature or gas. 3. The sensor is not sensitive to a small amount of dirt, but it should also be cleaned regularly when it is used in a dirty environment.

China LUGB Intelligent Vortex Flow Meter - China Gas

China LUGB Intelligent Vortex Flow Meter, Find details about China Gas Flowmeter, Vortex Flow Meter from LUGB Intelligent Vortex Flow Meter - Nanjing Metran Measurement & Control Instrument Co., Ltd. China Smart Vortex Flow Meter RS485 Modbus Ouput Relying on our dedication and expertise in the industry, we use the most professional industry background to tailor the best solution for each customer, and strive to become the first-class supplier of turbine type water meter, liquid turbine flow meter, ultrasonic water flow meter price at home and abroad. Our company takes the quality as the foundation, the innovation as the direction

Compressed Air Insertion Flow Meters Sigma Sensing

SIGMA 430 HIGH TEMPERATURE (up to 200 °C) APPLICATIONS FLOW / CONSUMPTION SENSOR. Sigma 430 is an insertion type flow meter using the pitot tube principle, designed for flow and consumption measurement in wet air, high mass flow or high velocity applications. Installation requires a G3/4 connection and the mounting stem is graduated to simplify centering the sensor tip Easy Installation, High Accuracy, Gas Thermal Mass Flow MeterChina Easy Installation, High Accuracy, Gas Thermal Mass Flow Meter, Find details about China Thermal Mass Flow Meter, Thermal Mass Flowmeter from Easy Installation, High Accuracy, Gas Thermal Mass Flow Meter - Anhui Jujie Automation Technology Co., Ltd.

High Precision Digital Propane Flow Meter , KACISE Co2 Gas

Vortex flowmeter is based on the principle of Karman vortex research and production, mainly for industrial pipe flow measurement fluid medium, such as a gas, liquid, steam and other media. It features a small pressure loss, large measuring range, high accuracy in the measurement of actual volume flow is hardly affected by fluid density Insertion Electromagnetic Flowmeter - Flow Meter The AFTLD/C Insertion electromagnetic flow meter is Insertion Electromagnetic Flow Meterit was developed on the basis of a pipeline electromagnetic flow meter.It has the benefit of pipeline flow meter, and it also compensates for the difficulty in installation of the pipeline type electromagnetic flow meter and the high cost.

Insertion Thermal Mass Flow Meter - Q & T Instrument

Insertion Thermal Mass Flow Meter. Thermal gas mass flow meter is designed on the basis of thermal dispersion, and adopts method of constant differential temperature to measuring gas flow. It has advantages of small size, easy installation, high reliability and high accuracy, etc. The meter contains two platinum resistance temperature sensors. Insertion type electromagnetic flowmeter - MEGA InstrumentInsertion type electromagnetic flowmeter (MEGAMF4000) Item No.:6. MEGAMF4000 Series is a insert type electromagnetic flowmeter ideal for conductive liquids. It comes in sizes from 150mm to 3000mm. MEGAMF4000 Series is widely used for tap-water, waste water, food & beverage, Pulp & Paper and many other industrial fluid.

Insertion vortex flow meter - Magnetic flow meter, vortex

Insertion vortex flow meter is used in numerous branches of industry to measure the volume flow of liquids, gases and steam. Applications in the chemicals and petrochemicals industries, for example, in power generation and heat-supply systems involve widely differing fluids:saturated steam, superheated steam, compressed air, nitrogen, liquefied gases, flue gases, carbon dioxide, fully Integrated vortex flow meter-Felix Meter Co., Ltd.Integrated vortex flow meter works based on Carmen and Strouhal relevant spiral produce and on the theory of the flow relationship. Vortex flow meters measure flows of liquid, gas and steam by detecting the frequency at which vortices are alternatively shed from a bluff body.

LPG gas natural gas thermal mass flow meter, View LPG

Insertion type:DN50-DN2000mm . In-line type:DN10-DN2000mm. Tri-clamp & Thread type:DN15-100mm. Velocity:0.1-100Nm/s:Accuracy +/-1~2.5%:Working Temperature:Sensor:-40~+220 degC Transmitter:-20~+45 degC:Working Pressure:Insertion type 1.6Mpa . Flange type 4.0Mpa . Special pressure please double check. Power Supply Natural Gas Flow Meters -Sino-InstSino-Inst is a Professional Natural Gas Flow Meter manufacturer and supplier. Sino-Inst offers over 10 Natural Gas Flow Meter products. About 30% of these are turbine, vortex, ultrasonic, and thermal mass flow meters. Differential pressure flow meters. (orifice flow meter) are most widely used.

Nitrogen Gas Flow Meter Precision Flow Control

Gas Flow Meter Make Precision Flow Control Instruments Works On The Principle Of Thermal Mass Flow Measurement. Precision Flow Control Instruments Make Digital Gas Flow Meter balance out pressure fluctuations. It is designed with a thin film sensing element and its unique, sleek housing guarantees product recognition. General Applications Include The Gas Flow Measurement, Gas Flow S430 Pitot Tube Flow Sensor - Measure Monitor ControlS430 Air/Gas Flow Meter S430 is an insertion type flow meter using the pitot tube principle, designed for flow and consumption measurement in wet air, high mass flow or high velocity applications. Installation requires a G3/4 connection and the mounting stem is graduated to simplify centering the sensor tip for pipe sizes up to 10 diameter (DN250).

TGF450 THERMAL MA SS FLOW METER DAT ESHEET

Thermal mass flow meter datesheet 3 4. Process connection The TGF450 Series Thermal Flow meter has two different installation types, one is insertion and the other is in-line type. The insertion type can be installed and maintained on line. To install it, you have to weld and install a base with screw thread Thermal Gas Mass Flow Meter Tianjin Kailong Instrument Insertion Sensor:medium pressure 1.6MPa Flanged Sensor:medium pressure 1.6MPa Special pressure please contact us:Power:24VDC or 220VAC:Output:4-20mA/ Pulse /RS-485:Structural form:Plug-in type and Pipe type:Pipeline materials:Carbon steel, stainless steel,plastic, etc:Display:4 lines LCD Mass flow, Volume flow in standard condition, Flow totalizer,

Top Quality Thermal Gas Mass Flow Sensor With Lcd - Buy

Working Pressure Insertion Sensor:medium pressure 1.6MPa Flanged Sensor:medium pressure 1.6MPa Special pressure please contact us Power Supply Compact type:24VDC or 220VAC, Power consumption 18W Remote type:220VAC, Power consumption 19W Response Time 1s Output 4-20mA (optoelectronic isolation, maximum load 500), Pulse, Vortex Measuring Overiew - Industrial Flow Meter Steam:230 fps (70m/s),Gas: 11.5 fps (3.5m/s) 1.0% for liquid, 1.5% for gas/steam 230 psi (1.6MPa)up to 930 psi (6.8MPa) custom -30-662°F (-35-350) UL, CSA, FM, Class I Group B, C, D, Class II Groups E, F, G

Wholesale Thermal Gas Mass Flow Meter transmitter Biogas

Min. Order :1 Set Thermal Gas Mass Flow Meter transmitter Biogas flowmeter flow totalizer Note:Please be cautious and check with your supplier if this product is for virus protection purposes and if the coronavirus (COVID-19) will affect your order.Thermal Mass Flowmeters |Thermal gas mass flow meterThe insertion type thermal mass flowmeters can be installed and maintained online. Standard. with ball valve. flanged insertion. install/remove the meter without stopping the flow. for applications with. pressure higher than 1.6Mpa. for applications with. pressure higher than 1.6Mpa.